Configuring and Installing GPI-6050 modules
This document describes how to set up and install a HELM-GPI-6050 module.
Power Up
HELM GPI Modules require an external unregulated power supply of between 10 and 30V DC, at around 2W. Many standard plug-top or desktop supplies can be used. Connect the supply to the GPI module using the screw terminals, and apply power. The Status LED should flash RED when power is connected.
Ethernet
Connect the GPI Module to a network hub or switch via a standard CAT 5 network cable. The Status light should flash green/yellow, depending on the connection type and speed.
IP Address Configuration
Because the HELM-GPI-6050 module uses TCP/IP and Ethernet, it requires an IP Address and subnet mask like any other device connected over a LAN.
First, install the ADVANTECH “ADAM-5000TCP/6000” Utility software from the enclosed Mini-CD. Do not install any other software from this CD.

Follow the familiar install process…

Now, Launch the ADAM utility program. After a network search at startup, you will see a screen like this:

Select the ADAM6050 Module, and click the Network tab.
If you are asked for a PASSWORD, enter “00000000”.

You can now enter a suitable IP address and network mask for your GPI Module, and click “Apply”. Ask your network administrator to allocate you an IP address if your are unfamiliar with this.
Testing
Your GPI Module is now ready for use with HELM. To test this, download the GPI 6050 example panel, and adjust the IP address of the GPI-6050 icon to match. The Panel allows you to switch GPI outputs on and off, and to monitor the state of the 12 GPI input lines.
The ADAM Utility software is not typically required once your module IP address is configured. It is not used by HELM, and can be uninstalled if desired.